OUR UNIVERSAL PROTOCOL BRIDGE & TELEMETRY INTERFACE, M-BUS ADAPTER

The Mirach M-Bus Adapter bridges legacy wired M-Bus meters with modern IoT networks, wireless gateways, and industrial PLCs. It converts serial EN 13757 data streams into RS-485 Modbus, Sub-GHz RF, or pulse outputs.

Key Features & Architecture

Universal Protocol Translation

Translates M-Bus slave data into Modbus RTU / ASCII or pulse frequency signals transparently.

Wide Baud-Rate Support

Automatically synchronizes with M-Bus baud rates from 300 bps up to 9600 bps without manual dip-switch changes.

Low Power Consumption

Ultra-efficient power management draws minimal current from the host controller or auxiliary power supply.

Rugged In-Line Enclosure

Compact form factor fits directly into meter junction boxes, cable ducts, and cramped mechanical chases.

Transient Surge Suppression

Equipped with TVS diodes and current-limiting resistors to protect against induced lightning surges.

Ideal for integrating existing heat, water, and gas meters into new smart city or smart building management systems without expensive meter replacement or physical piping rework.

M-Bus Adapter Protocol Converter Hardware

Non-Invasive Sub-Metering Modernization Architecture

Replacing installed water or thermal meters involves plumbing disruptions, pipe draining, and high capital expense. The M-Bus Adapter connects non-invasively to the meter's existing communication terminals.

It samples consumption registers at configurable intervals, buffers values in non-volatile flash, and responds to host Modbus queries with zero latency.

  • Universal M-Bus Compatibility
  • Modbus RTU / ASCII Output
  • Auto-Baud Rate Detection
  • Ultra-Compact Form Factor
  • Surge & ESD Protected
  • Retrofit Without Re-Piping

Provides facility managers and energy auditors with instant digital visibility into legacy sub-metering installations.

Adapter Protocol Conversion Lifecycle

STEP 01

Signal Acquisition

The adapter intercepts raw differential voltage pulses from the slave meter M-Bus terminals.

STEP 02

Protocol Transformation

EN 13757 data records are decoded and mapped into standard 16-bit Modbus holding registers.

STEP 03

Host Transmission

The converted telemetry is served over RS-485 to supervisory SCADA or IoT gateway devices.

Retrofit Cost Savings & Reliability ROI

Operational Metrics & Parameters

  • Meter Replacement Cost Savings: Up to 70% vs New Meters
  • Installation & Commissioning Time: < 15 Minutes per Meter
  • Data Conversion Accuracy: 100% Bit-Exact Translation
  • Operational MTBF Rating: > 100,000 Hours

Supported Interfaces & Environments

Engineered for seamless integration into diverse building automation environments:

  • EN 13757 Slave Interface
  • RS-485 Modbus RTU
  • Pulse / Relay Output
  • BMS & PLC Interoperability
  • Industrial DIN Mounting
  • RoHS & CE Certified